Proof of Capability

Sample Reports

Redacted examples of an ERS commercial loss control survey and a residential home inspection. Client and location details are blacked out and the findings shown are illustrative, but the structure, detail and recommendations match what our clients receive.

Request Full Sample Set
Commercial Loss Control Survey
Risk Engineering & Loss Control Division
Redacted SampleIllustrative Findings
Report No.ERS-0000-000Survey Date00/00/0000
Carrier / MGACarrier Name RedactedPolicy No.000000000
Named InsuredInsured Name RedactedSurvey TypeNew Business Loss Control
LocationStreet Address Redacted, GeorgiaContact on SiteName, Owner

1. Executive Summary

Overall RiskAverageAcceptable with recommendations

The insured operates a full-service restaurant with an adjoining retail suite in a single-story, joisted masonry building. The building is in fair to good condition. Housekeeping is generally good. Four recommendations were made, two of high priority related to kitchen exhaust maintenance and a blocked exit. No conditions requiring immediate underwriting referral were observed. All recommendations were reviewed with the on-site contact.

2. Construction, Occupancy, Protection & Exposure (COPE)

Construction
Construction classJoisted masonry (ISO 2)
Year built1998
Stories / area1 story / approx. 8,400 sq ft
RoofModified bitumen, approx. 2016, fair condition
ElectricalBreaker panels, 400A service, no deficiencies noted
Occupancy
PrimaryFull-service restaurant, approx. 5,600 sq ft
SecondaryRetail suite, approx. 2,800 sq ft
CookingCommercial line with hood and wet chemical system
Hours7 days, 11 a.m. to 10 p.m.
Protection
SprinklersNone
Fire alarmCentral station monitored
Hood suppressionWet chemical, serviced within 6 months
Hydrant / fire dept.Hydrant approx. 300 ft; station approx. 2 mi
ExtinguishersABC and Class K present; see Rec. 2
Exposure
NorthParking lot, no exposure
EastMasonry retail building, approx. 40 ft
SouthPublic road
WestWooded lot, approx. 75 ft

3. Recommendations

No.Condition ObservedRecommendationPriority
1Visible grease accumulation in kitchen hood and exhaust duct; last cleaning documented approx. 9 months ago.Clean hood, filters, ductwork and exhaust fan per NFPA 96 and keep service records on site.High
2Annual inspection tags on 3 portable extinguishers expired.Have all portable extinguishers inspected and tagged per NFPA 10.Medium
3Rear exit corridor partially blocked by stored boxes.Keep exit routes clear at all times; relocate storage.High
4Debris collected around two roof drains.Clear roof drains and add to a quarterly roof maintenance schedule.Low

4. Photo Log

Photo 1
Front elevation (identifying signage redacted)
Photo 2
Kitchen hood and suppression nozzles
Photo 3
Grease accumulation at duct access (Rec. 1)
Photo 4
Expired extinguisher tag (Rec. 2)
Photo 5
Rear exit corridor storage (Rec. 3)
Photo 6
Roof surface and drains (Rec. 4)

Full reports include all field photos, typically 25 to 60 per location.

5. Quality Control & Certification

  • ✓ Scope confirmed with client before dispatch
  • ✓ Standardized field checklist completed
  • ✓ All recommendations reviewed with on-site contact
  • ✓ Report reviewed in-house before release

Surveyed by: Field Consultant Name  ·  Reviewed by: QC Reviewer  ·  Emergent Risk & Safety, LLC

This sample is provided to show report format and level of detail. Client, insured and location details are redacted and the findings are illustrative. Loss control surveys document conditions observed at the time of the visit and are not engineering, code compliance or warranty inspections.

Full Home Inspection Report
Safety, Compliance & Property Inspections Division
Redacted SampleIllustrative Findings
Report No.FL-0000-000Inspection Date00/00/0000
ClientClient Name RedactedInspection TypeFull Home (Buyer)
PropertyStreet Address Redacted, GeorgiaWeatherClear, approx. 72°F
HomeSingle-family, 2 stories, built 2004, approx. 2,150 sq ftPresentClient, buyer's agent

1. Summary

Overall ConditionGoodTypical for age, with items to address

The home is in good overall condition for its age. The items below are grouped by priority so you know what to handle first.

2 Safety4 Repair4 Maintenance

2. Systems Overview

SystemObservedRating
RoofArchitectural asphalt shingles, approx. 12 years old; minor granule lossSatisfactory
Exterior & gradingFiber cement siding; one downspout drains at foundationRepair
Foundation & structureCrawlspace; no significant movement observedSatisfactory
Electrical200A panel; kitchen counter receptacles not GFCI protectedSafety
PlumbingPEX supply; slow drip at kitchen sink trapRepair
Water heater50-gal gas, approx. 9 years old; operatingSatisfactory
HVACSplit system heat pump, approx. 10 years old; dirty filterRepair
Attic & insulationBlown-in insulation, approx. R-30; ventilation adequateSatisfactory
Interior & safety devicesNo smoke alarm in one bedroomSafety

3. Findings & Recommendations

No.FindingRecommendationPriority
1Kitchen counter receptacles are not GFCI protected.Have a licensed electrician install GFCI protection.Safety
2No smoke alarm in the rear bedroom.Install a smoke alarm in each bedroom and test all alarms.Safety
3Slow drip at the kitchen sink drain trap; minor staining in cabinet.Have a plumber repair the trap and check the cabinet floor.Repair
4Left-side downspout discharges against the foundation.Add an extension to carry water at least 4 to 6 feet away.Repair
5HVAC filter dirty; no recent service record.Replace the filter and have the system serviced by an HVAC contractor.Repair
6Loose handrail at the stairway.Secure the handrail to the wall framing.Repair
7Worn caulk at the primary tub and shower.Remove and re-caulk to prevent water intrusion.Maintenance
8Debris in front gutters.Clean gutters at least twice a year.Maintenance

Two additional maintenance items are listed in the full report.

4. Photo Log

Photo 1
Front elevation (house number redacted)
Photo 2
Roof surface and flashing
Photo 3
Electrical panel, cover removed
Photo 4
Non-GFCI kitchen receptacle (Finding 1)
Photo 5
Sink trap drip and staining (Finding 3)
Photo 6
Downspout at foundation (Finding 4)

Full reports include all inspection photos, typically 60 to 120 per home.

5. Quality Control

  • ✓ Inspected to InterNACHI Standards of Practice
  • ✓ Every finding photographed
  • ✓ Findings reviewed with client on site
  • ✓ Report reviewed in-house before release

Inspected by: Certified Inspector Name  ·  Emergent Risk & Safety, LLC

This sample is provided to show report format and level of detail. Client and property details are redacted and the findings are illustrative. A home inspection is a visual, non-invasive evaluation of readily accessible systems at the time of inspection and is not a guarantee, warranty or code compliance inspection.